Add configurable temperature threshold and improved relay control
- Add temperature threshold downlink command (t + temperature) - Update relay control: r1 0=force OFF, r1 1=enable auto control - Temperature threshold range validation (10-35°C) - Enhanced logging for better debugging
This commit is contained in:
parent
4850d5b257
commit
c46a47e125
@ -13,6 +13,7 @@ LOG_MODULE_REGISTER(lorawan_class_a);
|
||||
|
||||
extern bool relais_state;
|
||||
extern bool relais_manual_override;
|
||||
extern uint8_t temperature_threshold;
|
||||
const static struct device *lora_dev;
|
||||
static struct lorawan_join_config join_cfg;
|
||||
static uint8_t dev_eui[8];
|
||||
@ -41,13 +42,40 @@ static void dl_callback(uint8_t port, uint8_t flags, int16_t rssi, int8_t snr, u
|
||||
{
|
||||
uint8_t relais_value = hex_data[3];
|
||||
LOG_INF("Received relais1 state change: %d", relais_value);
|
||||
if (get_relais_state() != relais_value)
|
||||
|
||||
if (relais_value == 0)
|
||||
{
|
||||
set_relais_state(relais_value);
|
||||
LOG_INF("Set relais 1 value");
|
||||
/* r1 0: Force relais OFF and disable temperature control */
|
||||
relais_state = 0;
|
||||
relais_manual_override = true;
|
||||
set_relais_state(0);
|
||||
LOG_INF("Relais forced OFF, temperature control disabled");
|
||||
}
|
||||
else if (relais_value == 1)
|
||||
{
|
||||
/* r1 1: Re-enable automatic temperature control */
|
||||
relais_manual_override = false;
|
||||
LOG_INF("Automatic temperature control re-enabled");
|
||||
}
|
||||
else
|
||||
{
|
||||
LOG_WRN("Invalid relais command value: %d (valid: 0=OFF, 1=AUTO)", relais_value);
|
||||
}
|
||||
}
|
||||
/* Temperature threshold command: t[temp] (e.g., "t18" for 18°C) */
|
||||
else if (len > 2 && hex_data[0] == 't')
|
||||
{
|
||||
uint8_t new_threshold = hex_data[1];
|
||||
if (new_threshold >= 10 && new_threshold <= 35) // Valid range 10-35°C
|
||||
{
|
||||
temperature_threshold = new_threshold;
|
||||
relais_manual_override = false; // Re-enable automatic control
|
||||
LOG_INF("Temperature threshold updated to %d°C, automatic control enabled", temperature_threshold);
|
||||
}
|
||||
else
|
||||
{
|
||||
LOG_WRN("Invalid temperature threshold %d°C (valid range: 10-35°C)", new_threshold);
|
||||
}
|
||||
relais_state = relais_value;
|
||||
relais_manual_override = true;
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
@ -15,6 +15,7 @@ LOG_MODULE_REGISTER(g2h_heat_main);
|
||||
|
||||
volatile bool relais_state = false;
|
||||
volatile bool relais_manual_override = false;
|
||||
volatile uint8_t temperature_threshold = 21;
|
||||
|
||||
/* MAIN */
|
||||
int main(void)
|
||||
@ -46,14 +47,14 @@ int main(void)
|
||||
|
||||
/* Set relais based on temperature if not manually overridden */
|
||||
if (!relais_manual_override) {
|
||||
if (temp < 21.0) {
|
||||
relais_state = 1; // Heat on below 21°C
|
||||
if (temp < temperature_threshold) {
|
||||
relais_state = 1; // Heat on below threshold
|
||||
} else {
|
||||
relais_state = 0; // Heat off at/above 21°C
|
||||
relais_state = 0; // Heat off at/above threshold
|
||||
}
|
||||
set_relais_state(relais_state);
|
||||
}
|
||||
printk("relais: %d (manual: %d)\n", relais_state, relais_manual_override);
|
||||
printk("relais: %d (manual: %d, threshold: %d°C)\n", relais_state, relais_manual_override, temperature_threshold);
|
||||
|
||||
/* Pack and send values */
|
||||
char data[7];
|
||||
|
||||